Technical Specification

 

Efficiency

Max. efficiency 98.6% @400V, 98.8% @480V
European efficiency 98.4%

 

Input

Max. Input Voltage 1,100 V
Max. Short Circuit Current 66 A
Operating Voltage Range 200 V ~ 1,000 V
Max. input number 12

 

Output

Nominal AC Active Power 150,000 W
Max. AC Apparent Power 165,000 VA
Max. AC Active Power (cosφ=1) 165,000 W
Nominal Output Voltage 380 V/400 V/480Vac
Rated AC Grid Frequency 50 Hz / 60 Hz
Nominal Output Current 227.9 A @380 V, 216.5A @400 V, 180.4A @480Vac
Max. Output Current 253.2A @380 V, 240.5A @400 V, 200.5A @480Vac
Adjustable Power Factor Range 0.8 leading… 0.8 lagging
alternating current THDi <1%

 

Protection

Anti-islanding Protection Yes
AC Overcurrent Protection Yes
DC Surge Arrester Type II
AC Surge Arrester Type II
DC Insulation Resistance Detection Yes
Residual Current Monitoring Unit Yes
Smart String Level Disconnector Yes
Arc Fault Protection Yes
Smart Connector Temperature Detector Yes
PID Recovery Yes
PV Ground-Fault Protection Yes

 

Communication

Display LED indicators;  WLAN adaptor + FusionSolar APP
RS485/ USB Yes
Smart Dongle-4G Smart Dongle – 4G / WLAN (Optional)
Monitoring BUS (MBUS) Yes (Isolation Transformer Required)

 

General Data

Dimensions (W x H x D) 1,000 x 710 x 395 mm
Weight (withoutmounting plate) ≤100 kg
Operating Temperature Range -25°C ~ 60°C
Cooling Method Smart Air Cooling
Max. Operating Altitude 4,000 m (13,123ft.)
Relative Humidity 0 ~ 100%
DC Connector Amphenol HH4
AC Connector Waterproof Connector + OT/DT Terminal
Protection Degree IP66

 

Standard Compliance (more available upon request)

Certificate : EN 62109-1/ 2, IEC 62109 1/ 2, IEC 62116, IEC 61727, IEC 60068, IEC 61683
Grid Connection Standards : VDE-AR N4105, EN 50549 1, EN 50549 2, RD 661, RD 1699, C10/11

 

*1. The maximum power of PV module at STC shall NOT exceed the “Rated input DC power” of MERC 1100/1300W P. PV Modules with up to 10% power tolerance are allowed.
*2. Any power optimizer, which is connected to an operating inverter in a PV string, will be bypassed when it fails.
*3. When the MERC 1100/1300W P is disconnected from inverter or when the inverter is off, its output voltage will be 1 V.
*4. It is for PV module frame/extruded aluminum profile racking system installation.
*5. Pay attention to PV module wire length. To match PV modules with a split junction box and short output wire, the long input cabl e version (input wire: 1.3 m(+/ m(+/–); output wire 0.1m(+)/2.9m (–)) of MERC 1100/1300W P is available upon request.
*6. When the operating temperature of the MERC 1100/1300W P reaches 70 to 85 ℃℃, it may shut down due to over temperature protection and report an over temperature alarm. After the temperature decreases, it can automatically resume working without any damage.
*7. Each PV module under the same inverter must be equipped with a MERC 1100/1300W P.
*8. SUN2000 450W P2/600W P and MERC 1100/1300W P can NOT be used in mixture under the same Smart Energy/PV controller.
*9. It is recommended that strings under the same inverter have an equal capacity. If it is not feasible, the capacity difference be tween strings under the same inverter must not exceed 2 kW. Otherwise, the energy yield will be reduced.

 

For using inverters together with optimizers and batteries we advise you to always check the compatibility in the datasheets, or ask your dealer for advice.