Introducing the leading multi-peak MPPT algorithm and PID recovery solution, the all-new SUN5000-150K-MG0 takes power production to the next level, achieving utmost efficiency without power degradation.
Max. efficiency | 98.6% @400V, 98.8% @480V |
European efficiency | 98.4% |
Max. Input Voltage | 1,100 V |
Max. Short Circuit Current | 66 A |
Operating Voltage Range | 200 V ~ 1,000 V |
Max. input number | 12 |
Nominal AC Active Power | 150,000 W |
Max. AC Apparent Power | 165,000 VA |
Max. AC Active Power (cosφ=1) | 165,000 W |
Nominal Output Voltage | 380 V/400 V/480Vac |
Rated AC Grid Frequency | 50 Hz / 60 Hz |
Nominal Output Current | 227.9 A @380 V, 216.5A @400 V, 180.4A @480Vac |
Max. Output Current | 253.2A @380 V, 240.5A @400 V, 200.5A @480Vac |
Adjustable Power Factor Range | 0.8 leading… 0.8 lagging |
alternating current THDi | <1% |
Anti-islanding Protection | Yes |
AC Overcurrent Protection | Yes |
DC Surge Arrester | Type II |
AC Surge Arrester | Type II |
DC Insulation Resistance Detection | Yes |
Residual Current Monitoring Unit | Yes |
Smart String Level Disconnector | Yes |
Arc Fault Protection | Yes |
Smart Connector Temperature Detector | Yes |
PID Recovery | Yes |
PV Ground-Fault Protection | Yes |
Display | LED indicators; WLAN adaptor + FusionSolar APP |
RS485/ USB | Yes |
Smart Dongle-4G | Smart Dongle – 4G / WLAN (Optional) |
Monitoring BUS (MBUS) | Yes (Isolation Transformer Required) |
Dimensions (W x H x D) | 1,000 x 710 x 395 mm |
Weight (withoutmounting plate) | ≤100 kg |
Operating Temperature Range | -25°C ~ 60°C |
Cooling Method | Smart Air Cooling |
Max. Operating Altitude | 4,000 m (13,123ft.) |
Relative Humidity | 0 ~ 100% |
DC Connector | Amphenol HH4 |
AC Connector | Waterproof Connector + OT/DT Terminal |
Protection Degree | IP66 |
Certificate : EN 62109-1/ 2, IEC 62109 1/ 2, IEC 62116, IEC 61727, IEC 60068, IEC 61683
Grid Connection Standards : VDE-AR N4105, EN 50549 1, EN 50549 2, RD 661, RD 1699, C10/11
*1. The maximum power of PV module at STC shall NOT exceed the “Rated input DC power” of MERC 1100/1300W P. PV Modules with up to 10% power tolerance are allowed.
*2. Any power optimizer, which is connected to an operating inverter in a PV string, will be bypassed when it fails.
*3. When the MERC 1100/1300W P is disconnected from inverter or when the inverter is off, its output voltage will be 1 V.
*4. It is for PV module frame/extruded aluminum profile racking system installation.
*5. Pay attention to PV module wire length. To match PV modules with a split junction box and short output wire, the long input cabl e version (input wire: 1.3 m(+/ m(+/–); output wire 0.1m(+)/2.9m (–)) of MERC 1100/1300W P is available upon request.
*6. When the operating temperature of the MERC 1100/1300W P reaches 70 to 85 ℃℃, it may shut down due to over temperature protection and report an over temperature alarm. After the temperature decreases, it can automatically resume working without any damage.
*7. Each PV module under the same inverter must be equipped with a MERC 1100/1300W P.
*8. SUN2000 450W P2/600W P and MERC 1100/1300W P can NOT be used in mixture under the same Smart Energy/PV controller.
*9. It is recommended that strings under the same inverter have an equal capacity. If it is not feasible, the capacity difference be tween strings under the same inverter must not exceed 2 kW. Otherwise, the energy yield will be reduced.
For using inverters together with optimizers and batteries we advise you to always check the compatibility in the datasheets, or ask your dealer for advice.
To provide the best experiences, we use technologies such as cookies to store and/or access information about your device. By consenting to these technologies, we can process data such as browsing behavior or unique IDs on this site. If you do not consent or withdraw your consent, it may adversely affect certain features and functions.